Background and Development

Semax is a synthetic heptapeptide developed in the Soviet Union during the 1980s by researchers at the Institute of Molecular Genetics in Moscow. It was designed as a truncated analog of adrenocorticotropic hormone, retaining only the fragment spanning residues four through ten. Investigators sought a peptide that would preserve the cognitive effects associated with ACTH while eliminating the hormonal stimulation of the adrenal cortex. The compound entered clinical use in Russia during the following decade.

Russian regulatory authorities approved the peptide for nasal administration, and it remains listed in the national pharmacopoeia under several trade names. Documented indications include acute ischemic stroke, transient ischemic attacks, traumatic brain injury, and certain ophthalmological and neurological conditions. Physicians also prescribe it for cognitive complaints in older patients, although the evidence base for that use is thinner. Outside Russia and a few neighboring states, the substance is not an approved medicine and is sold instead as a research chemical.

化学性质与分析表征

从分子层面看,Semax 是线性七肽,没有二硫键、糖基或脂链修饰,N 端为游离氨基,C 端为游离羧基。分子含组氨酸与谷氨酸侧链,因此在水和甲醇等极性溶剂中溶解良好,在非极性溶剂中溶解有限。计算分子量约为 814 Da,与其质子化离子的质荷比吻合,可用于质谱确认。

稳定性主要由水解与氧化两条路径支配。肽键在中性或弱酸性条件下相对稳定,遇到强碱或长时间高温则明显断裂;甲硫氨酸侧链容易被氧化成亚砜,使主峰前移并拉低实际含量。金属离子、光照和反复冻融会进一步促进降解或聚集。冻干粉在低温避光条件下可存放较长时间,配制后的水溶液通常需要冷藏并尽快用完。

纯度评估以反相高效液相色谱为主,通过主峰面积百分比给出粗略结果,再配合电喷雾质谱核对分子量。氨基酸分析可验证组成比例,手性色谱或毛细管电泳用于检查残基构型。常见杂质包括缺失序列的短肽、氧化产物与二聚体。由于多数市售品不附带完整检验报告,独立第三方检测常被用来核实标称值。

Semax at a glance

PropertyValueNotes
Molecular classSynthetic heptapeptideAnalog of an ACTH fragment
Amino acid lengthSeven residuesMet-Glu-His-Phe-Pro-Gly-Pro
OriginMoscow, 1980sInstitute of Molecular Genetics
Approved regionsRussia and some neighboring statesNot cleared in Western markets
Common trade namesMultiple national brandsSold as a nasal formulation

Semax Background And Mechanism

Semax is a synthetic heptapeptide with the sequence Met-Glu-His-Phe-Pro-Gly-Pro. It was derived from the ACTH(4-10) fragment, a short segment of adrenocorticotropic hormone that lacks the hormonal activity associated with the full-length peptide. Researchers at the Institute of Molecular Genetics in Moscow developed the compound during the 1980s. It has been registered as a pharmaceutical product in Russia and several neighbouring countries, where it is supplied as a nasal solution, and it is also sold internationally as a research chemical.

The proposed mechanism centres on neurotrophic signalling rather than direct receptor activation. Semax is reported to increase expression of brain-derived neurotrophic factor and nerve growth factor in several brain regions, and to shift the balance between excitatory and inhibitory neurotransmitter systems. Interaction with melanocortin receptors has been suggested because of the parent ACTH fragment. Many of these findings come from rodent studies, and the extent to which they translate to human physiology remains an open question.

Related pages on this site

Mechanism and Research Context

Published studies examine a fairly narrow set of endpoints. Rodent experiments commonly measure maze learning, infarct volume after induced ischemia, and tissue levels of neurotrophic factors. Clinical reports from Russian centres describe attention, memory and recovery scores in patients after stroke or transient ischemic attack. Most of those human studies are small and few have been repeated by independent groups. Outcome measures differ between studies, which limits direct comparison.

Circulation time for the peptide is short because peptidases cleave it readily. The Pro-Gly-Pro tail is thought to slow breakdown compared with the bare ACTH fragment, but the gain appears modest. Absorption after intranasal dosing is limited, and only a fraction of a dose is expected to reach the central nervous system. Laboratory concentrations therefore sit well above levels achieved systemically, a gap that complicates translation from bench findings to clinical claims.

Semax Peptide Structure and Origin

Semax is a synthetic heptapeptide with the sequence Met-Glu-His-Phe-Pro-Gly-Pro. Its design combines the ACTH(4-7) core fragment with a C-terminal Pro-Gly-Pro extension, a modification intended to improve stability and prolong activity. The molecule is hydrophilic, carries no lipid chains or glycosylation, and has a theoretical mass just over 810 daltons in its free form. All seven residues are proteinogenic amino acids, so no non-natural building blocks appear in the backbone. A free N-terminal methionine and C-terminal proline define the unmodified parent peptide.

The compound was developed during the 1980s at the Institute of Molecular Genetics in Moscow as part of research on fragments of adrenocorticotropic hormone. Early work examined short ACTH-derived sequences that retained neurotrophic effects while lacking the endocrine activity of the full hormone. Semax entered clinical use in Russia during the 1990s, where it received registration for several neurological indications. Outside that region it remained primarily a laboratory research material rather than an approved therapeutic. English-language literature on it grew more slowly and frequently cited the original Russian studies.

Terminology around the compound varies by source. It appears in catalogues and papers as Semax, as the heptapeptide ACTH(4-7)-Pro-Gly-Pro, and under various alphanumeric laboratory codes used by individual suppliers. These names refer to the same sequence but may imply different salt forms, purity grades, or counter-ions. Peptide databases usually list the free base mass, while product descriptions sometimes report acetate or trifluoroacetate salts with a different formula weight. Because naming conventions for research peptides are not standardised across vendors, checking the declared sequence and measured mass is more reliable than relying on a trade name alone.

Handling, Stability, and Quality Control

Routine characterization relies on reversed-phase high-performance liquid chromatography to establish purity and on mass spectrometry to confirm molecular identity. Electrospray ionization and matrix-assisted laser desorption ionization are both used for mass verification. Amino acid analysis and peptide mapping can detect sequence errors. Common impurities include truncated sequences, methionine sulfoxide formed by oxidation, and deamidated products. Chromatograms are usually recorded near 214 nm, where the peptide backbone absorbs, and purity is reported as the percentage area of the principal peak.

Verification of a supplied batch generally combines a certificate of analysis with independent testing, because certificates are self-reported documents. A typical package includes a chromatographic trace, a mass spectrum, and a stated water or counter-ion content. Batch-to-batch consistency matters more than a single purity figure when results are compared across experiments. No single mandatory standard governs research-grade peptide release, so laboratories are expected to define their own acceptance criteria. Residual trifluoroacetate from purification is a frequently overlooked counter-ion.

Lyophilized material is chemically stable for extended periods when kept dry, cold, and protected from light. The powder is hygroscopic, so vials should be warmed to room temperature before opening to reduce condensation on the contents. Once dissolved, the peptide is far less stable because peptide bonds are susceptible to hydrolysis and the methionine residue can oxidize. Solutions are typically aliquoted and held at 2-8 °C for short intervals or frozen for longer ones, and repeated freeze-thaw cycles should be avoided.

Further detail

Diabetes Research Center Einstein-Rockefeller-CUNY Center for AIDS Research Harold and Muriel Block Institute for Clinical and Translational Research at Einstein and Montefiore Institute for Aging Research Montefiore Einstein Comprehensive Cancer Center New York Regional Center for Diabetes Translation Research Rose F. Kennedy Intellectual and Developmental Disabilities Research Center

Brenipatide (INNTooltip International Nonproprietary Name, USANTooltip United States Adopted Name; developmental code name LY-3537031) is a dual agonist of glucagon-like peptide-1 (GLP-1) receptors and gastric inhibitory polypeptide (GIP) receptors. Brenipatide is under development by Eli Lilly and Company for the treatment of alcoholism, bipolar disorder, asthma, smoking withdrawal, cardiovascular disorders, liver disorders, metabolic disorders, and obesity. It is taken by subcutaneous injection once per month. The drug has a longer elimination half-life than tirzepatide or retatrutide. As of December 2025, it was in phase 3 clinical trials for alcoholism and bipolar disorder, phase 2 trials for asthma and smoking withdrawal, and phase 1 trials for cardiovascular disorders, liver disorders, metabolic disorders, and obesity.

An important technique for characterizing metal carbonyls is infrared spectroscopy. The C–O vibration, typically denoted νCO, occurs at 2143 cm−1 for carbon monoxide gas. The energies of the νCO band for the metal carbonyls correlates with the strength of the carbon–oxygen bond, and inversely correlated with the strength of the π-backbonding between the metal and the carbon. The π-basicity of the metal center depends on a lot of factors; in the isoelectronic series (titanium to iron) at the bottom of this section, the hexacarbonyls show decreasing π-backbonding as one increases (makes more positive) the charge on the metal. π-Basic ligands increase π-electron density at the metal, and improved backbonding reduces νCO. The Tolman electronic parameter uses the Ni(CO)3 fragment to order ligands by their π-donating abilities. The number of vibrational modes of a metal carbonyl complex can be determined by group theory. Only vibrational modes that transform as the electric dipole operator will have nonzero direct products and are observed. The number of observable IR transitions (but not their energies) can thus be predicted. For example, the CO ligands of octahedral complexes, such as Cr(CO)6, transform as a1g, eg, and t1u, but only the t1u mode (antisymmetric stretch of the apical carbonyl ligands) is IR-allowed. Thus, only a single νCO band is observed in the IR spectra of the octahedral metal hexacarbonyls. Spectra for complexes of lower symmetry are more complex. For example, the IR spectrum of Fe2(CO)9 displays CO bands at 2082, 2019 and 1829 cm−1.

Sources: en.wikipedia.org

Supporting material

Wireless networking – automated radio links which transmit digital data between computers and other wireless devices using radio waves, linking the devices together transparently in a computer network. Computer networks can transmit any form of data: in addition to email and web pages, they also carry phone calls (VoIP), audio, and video content (called streaming media). Security is more of an issue for wireless networks than for wired networks since anyone nearby with a wireless modem can access the signal and attempt to log in. The radio signals of wireless networks are encrypted using WPA. Wireless LAN (wireless local area network or Wi-Fi) – based on the IEEE 802.11 standards, these are the most widely used computer networks, used to implement local area networks without cables, linking computers, laptops, cell phones, video game consoles, smart TVs and printers in a home or office together, and to a wireless router connecting them to the Internet with a wire or cable connection. Wireless routers in public places like libraries, hotels and coffee shops create wireless access points (hotspots) to allow the public to access the Internet with portable devices like smartphones, tablets or laptops. Each device exchanges data using a wireless modem (wireless network interface controller), an automated microwave transmitter and receiver with an omnidirectional antenna that works in the background, exchanging data packets with the router.

protoplast A plant, fungal, or bacterial cell which has had its cell wall removed by mechanical, chemical, or enzymatic means; or the complete contents (the protoplasm) of an intact cell excluding the cell wall.

=== Magnetic drug targeting === An important task in cancer research is developing more precise methods for delivering medicine to affected areas. One method involves binding of medicine to biologically compatible magnetic particles (such as ferrofluids), which are guided to the target through careful placement of permanent magnets on the exterior of the body. Magnetohydrodynamic equations and finite element analysis are used to study interactions between magnetic fluid particles in the bloodstream and the external magnetic field.

Sources: en.wikipedia.org

Notes from published material

== Mission parameters == Mass: 3,570 kg (7,870 lb) Perigee (insertion): 165.8 km (103.0 mi; 89.5 nmi) Apogee (insertion): 293.7 km (182.5 mi; 158.6 nmi) Period: 88.94 min Inclination: 32.53° Perigee (last orbit): 150 km (93 mi; 81 nmi) Apogee (last orbit): 232.8 km (144.7 mi; 125.7 nmi)

== See also == Isotope List of elements by stability of isotopes List of nuclides (sorted by half-life) Table of nuclides Alpha nuclide Monoisotopic element Mononuclidic element Primordial element Radionuclide Hypernucleus

=== Leaves === Average yields of 6 tons/ha/year (2 tons per acre) in fresh matter can be achieved. The harvest differs strongly between the rainy and dry seasons, with 1120 kilogram/ha (1000 lb per acre) per harvest and 690 kg/ha (620 lb per acre) per harvest, respectively. The leaves and stems can be harvested from the young plants 60 days after seeding and then another seven times in the year. At every harvest, the plants are cut back to within 60 cm (2') of the ground. In some production systems, the leaves are harvested every 2 weeks. The cultivation of M. oleifera can also be done intensively with irrigation and fertilization with suitable varieties. Trials in Nicaragua with 1 million plants per hectare and 9 cuttings/year over 4 years gave an average fresh matter production of 580 metric tons/ha/year (230 long tons per acre), equivalent to about 174 metric tons of fresh leaves.

ångström (Å) A non-SI, metric unit of length equal to 10−10 metre, i.e. 1⁄10000000000 of a metre or 0.1 nanometre. The angstrom is commonly used in the natural sciences to express microscopic or atomic-scale distances, including the sizes of atomic nuclei, wavelengths of electromagnetic radiation, and lengths of chemical bonds (e.g. the covalent radius of a chlorine atom averages about 1 angstrom).

Sources: en.wikipedia.org

Frequently asked questions

Where was Semax developed?

It originated at the Institute of Molecular Genetics in Moscow during the 1980s. The work was carried out by a Russian research group that specialized in peptide neuropharmacology.

Is Semax an approved medication anywhere?

It is registered as a medicine in Russia and has been used clinically there for decades. No regulatory agency in Western Europe or North America has approved it for any indication.

What is the relationship to ACTH?

Semax corresponds to the four-to-ten fragment of adrenocorticotropic hormone. Because it omits the first three residues, it lacks the adrenal-stimulating action of the full hormone.

用什么方法确认分子量?

电喷雾或基质辅助激光解吸电离质谱是常用手段,测得的质子化离子质荷比可换算为分子量。结果与理论值落在合理误差内,才支持结构一致的判断。